Comparative clinical performance - gFOBT and iFOBT
In the USA, Allison et al. (2007) prospectively compared two types of FOBTs, a sensitive gFOBT
(Hemoccult SENSA) and a manual iFOBT (Flexsure). A large number of patients (7394 subjects were
eligible for the study) were requested to perform both tests. All patients positive for either FOBTs
were invited to have a total colonoscopy, whereas all patients negative to FOBT were advised to have
a sigmoidoscopy. All cancers occurring during the two years following the test were identified, so that
it was possible to estimate the absolute sensitivity and specificity for detecting advanced neoplasms in
the left colon within two years after the FOBT screening for the two tests administered separately and
in combination. The sensitivity for detecting cancer was 81.8% (95% CI = 47.8% to 96.8%) for the
iFOBT and 64.3% (95% CI = 35.6% to 86.0%) for the gFOBT. The sensitivity for detecting distal
advanced adenomas was higher for gFOBT than for iFOBT 41.3% (95% CI = 32.7% to 50.4%) vs
29.5% (95% CI = 21.4% to 38.9%). PPV was much higher for iFOBT than for gFOBT for distal cancer
(5.2% and 1.5% for iFOBT and gFOBT respectively) and for advanced adenomas (19.1 and 8.9% for
iFOBT and gFOBT respectively). The authors concluded that iFOBT has high sensitivity and specificity
for detecting left-sided colorectal cancer and that it may be a useful replacement for the gFOBT.
The study by Dancourt et al. (2008) compared the performance of a 3-day gFOBT and 2-day iFOBT in
17 215 subjects. For 1205 subjects who participated and had colonoscopy, the PPV for the guaiac and
immunochemical test was respectively 5.9% v 5.2% for cancer and 27.2% and 17.5% for adenoma.
The study by van Rossum et al. (2008) represents a milestone in the comparison of gFOBT with
iFOBT, being the first randomised trial in a population based screening setting. A large number of
people (20 623) aged 50–75 years were randomised to either gFOBT (Hemoccult II, Beckman Coulter
Inc. Fullerton, CA, USA) or iFOBT (OC-Sensor). For iFOBT, the standard cut-off of 100 ng/mL was
used. iFOBTs showed higher compliance than did gFOBTs (56.9% vs 46.9% respectively p<.01). The
positivity rate was significantly higher in iFOBTs compared to gFOBTs (5.0% vs. 2.4% respectively,
p<0.01). Cancer or advanced adenomas were found, respectively, in 11 and 46 of gFOBTs and in 24
and 121 of iFOBTs. The detection rate per 1000 examinations for cancer was 71% higher in iFOBT
compared to gFOBT; the detection rate per 1000 examinations for advanced adenomas was 106%
higher in iFOBT as compared to gFOBT. The number-to-scope to find 1 cancer or 1 adenoma was
comparable between the tests, with the PPV not statistically different. In conclusion, iFOBT compared
to gFOBT demonstrated a higher detection rate with a similar PPV.
The results of these five studies are consistent with data from the first European screening programmes.
The UK Pilot study adopted Hema-screen, a conventional non-rehydrating gFOBT, using
duplicate samples on 3 consecutive stools extended to 2 further sets of 3 stools if indicated. This UK
pilot study gave a positivity rate during the first round of 1.9%. The Detection Rates (DR) for cancer
and neoplasia (cancer and advanced or non-advanced adenoma) were 1.62 in 1000 and 6.91 in 1000
respectively. The PPV for neoplasia was 46.9% in England and 47.3% in Scotland (UK Colorectal
Cancer Screening Pilot Group 2004).